Question 1 of 20
1. Question
In a commercial facility where power supply conductors and sensitive communication circuits share the same raceway system, what is the most effective measure for mitigating electromagnetic interference (EMI)?
Correct
Correct: Utilizing grounded metallic dividers or maintaining specific separation distances is a recognized method in national electrical safety codes to prevent electromagnetic disturbances from power circuits affecting communication signals.
Incorrect: The strategy of twisting power and data cables together increases interference rather than canceling it. Choosing to bond to plumbing pipes is an unreliable grounding method that fails to provide a proper low-impedance path. Focusing on reducing the size of grounding conductors is dangerous and increases impedance, which compromises both safety and noise mitigation.
Takeaway: Effective EMI mitigation requires physical separation or grounded metallic shielding between power and sensitive communication circuits.
Incorrect
Correct: Utilizing grounded metallic dividers or maintaining specific separation distances is a recognized method in national electrical safety codes to prevent electromagnetic disturbances from power circuits affecting communication signals.
Incorrect: The strategy of twisting power and data cables together increases interference rather than canceling it. Choosing to bond to plumbing pipes is an unreliable grounding method that fails to provide a proper low-impedance path. Focusing on reducing the size of grounding conductors is dangerous and increases impedance, which compromises both safety and noise mitigation.
Takeaway: Effective EMI mitigation requires physical separation or grounded metallic shielding between power and sensitive communication circuits.
-
Question 2 of 20
2. Question
A FINRA-regulated brokerage firm in the United States is upgrading its data center with new low-voltage signaling systems to monitor server temperatures. To ensure compliance with the National Electrical Code (NEC) and mitigate operational risk, the project manager must verify the classification of the power sources for these circuits. What is the primary safety characteristic required for a Class 2 power-limited circuit in this installation?
Correct
Correct: Under the National Electrical Code (NEC), Class 2 circuits are designed to provide safety from both fire and electric shock by limiting the power available from the source, typically through a listed transformer or power supply that restricts energy output.
Incorrect
Correct: Under the National Electrical Code (NEC), Class 2 circuits are designed to provide safety from both fire and electric shock by limiting the power available from the source, typically through a listed transformer or power supply that restricts energy output.
-
Question 3 of 20
3. Question
When installing electrical branch circuits in a Category 1 (Critical Care) patient care space, which grounding configuration is required by United States safety standards to mitigate the risk of electric shock?
Correct
Correct: In the United States, the National Electrical Code (NEC) Section 517.13 requires redundant grounding in patient care spaces. This mandate ensures that if one grounding path fails, a second path remains to protect patients from leakage currents. The installation must use a metallic raceway or cable armor as the first path and an insulated copper conductor as the second path.
Incorrect
Correct: In the United States, the National Electrical Code (NEC) Section 517.13 requires redundant grounding in patient care spaces. This mandate ensures that if one grounding path fails, a second path remains to protect patients from leakage currents. The installation must use a metallic raceway or cable armor as the first path and an insulated copper conductor as the second path.
-
Question 4 of 20
4. Question
Following an on-site examination at a major clearing house in the United States, SEC regulators identified a risk in the firm’s operational resilience framework regarding the electrical infrastructure of its primary data center. The internal audit team noted that the overcurrent protective devices were not properly coordinated, potentially leading to a total power loss from a single branch circuit fault. When selecting overcurrent devices to mitigate this risk, what principle must be applied to ensure that only the protective device immediately upstream of a fault disconnects the circuit?
Correct
Correct: Selectivity is the requirement that the protective device closest to the fault operates before any upstream devices. This is achieved by analyzing the time-current curves to ensure the downstream device clears the fault first. For US financial institutions, this is a critical component of operational resilience overseen by the SEC to prevent unnecessary system downtime.
Incorrect
Correct: Selectivity is the requirement that the protective device closest to the fault operates before any upstream devices. This is achieved by analyzing the time-current curves to ensure the downstream device clears the fault first. For US financial institutions, this is a critical component of operational resilience overseen by the SEC to prevent unnecessary system downtime.
-
Question 5 of 20
5. Question
A compliance officer at a United States rail transport company is conducting a safety audit of the electrical systems installed on a new series of diesel-electric locomotives. During the review of the National Electrical Code (NEC), the officer must determine the extent to which NFPA 70 standards apply to the onboard traction power systems and control circuits of these rail vehicles.
Correct
Correct: According to Article 90.2(B)(3) of the National Electrical Code (NFPA 70), the code does not cover installations of railways for the generation, transformation, transmission, or distribution of power used exclusively for the operation of rolling stock. In the United States, these specific installations fall under the jurisdiction of federal agencies such as the Federal Railroad Administration (FRA), which establishes specialized safety standards for rail equipment.
Incorrect: Relying on a general voltage threshold of 50 volts ignores the specific jurisdictional exclusions for specialized transportation equipment defined in the code’s scope. The strategy of splitting jurisdiction between passenger areas and traction systems is incorrect because the entire vehicle is typically excluded from NEC application. Focusing on the duration of connection to a stationary power source misinterprets the fundamental exclusion of rolling stock from the code. Opting to apply the NEC to all US installations fails to account for the specific exemptions granted to rail utilities under federal law.
Takeaway: The National Electrical Code (NEC) excludes locomotives and rolling stock from its scope, as these are governed by federal transportation regulations.
Incorrect
Correct: According to Article 90.2(B)(3) of the National Electrical Code (NFPA 70), the code does not cover installations of railways for the generation, transformation, transmission, or distribution of power used exclusively for the operation of rolling stock. In the United States, these specific installations fall under the jurisdiction of federal agencies such as the Federal Railroad Administration (FRA), which establishes specialized safety standards for rail equipment.
Incorrect: Relying on a general voltage threshold of 50 volts ignores the specific jurisdictional exclusions for specialized transportation equipment defined in the code’s scope. The strategy of splitting jurisdiction between passenger areas and traction systems is incorrect because the entire vehicle is typically excluded from NEC application. Focusing on the duration of connection to a stationary power source misinterprets the fundamental exclusion of rolling stock from the code. Opting to apply the NEC to all US installations fails to account for the specific exemptions granted to rail utilities under federal law.
Takeaway: The National Electrical Code (NEC) excludes locomotives and rolling stock from its scope, as these are governed by federal transportation regulations.
-
Question 6 of 20
6. Question
A compliance officer at a US-based, SEC-registered real estate investment trust is reviewing the electrical safety specifications for a new residential development to ensure NEC compliance. The project involves the installation of multiple interconnected smoke alarms across several three-story townhomes. For the installation of these safety devices in new construction, which power source configuration is required by US national standards?
Correct
Correct: Under US standards such as the NEC and NFPA 72, smoke alarms in new residential construction are required to be hardwired to the building’s primary electrical system and must also include a secondary battery backup to ensure they function during power outages.
Incorrect: Relying solely on batteries is generally restricted to existing buildings where no major electrical work is being performed. The strategy of using a dedicated circuit is not a requirement and is often discouraged because a tripped breaker might not be noticed immediately. Opting for a Class 2 transformer connection to a telecommunications hub does not meet the primary power requirements for residential smoke alarm systems.
Incorrect
Correct: Under US standards such as the NEC and NFPA 72, smoke alarms in new residential construction are required to be hardwired to the building’s primary electrical system and must also include a secondary battery backup to ensure they function during power outages.
Incorrect: Relying solely on batteries is generally restricted to existing buildings where no major electrical work is being performed. The strategy of using a dedicated circuit is not a requirement and is often discouraged because a tripped breaker might not be noticed immediately. Opting for a Class 2 transformer connection to a telecommunications hub does not meet the primary power requirements for residential smoke alarm systems.
-
Question 7 of 20
7. Question
A facility engineer at a data center in the United States is specifying the requirements for functional switching devices on a new 208V server rack power distribution unit. These devices will be used for routine operational control of the equipment. According to the National Electrical Code (NEC) standards for functional switching, what is a primary requirement for these devices?
Correct
Correct: Functional switching is intended for the routine control of electrical circuits under normal conditions. Therefore, the device must be specifically rated to handle the load current it will encounter during its service life to prevent overheating or failure.
Incorrect: Relying on a visible break in the circuit is a requirement for safety isolation under OSHA standards rather than functional control. Simply providing an adjustable trip unit focuses on the protective functions of a circuit breaker rather than the operational switching requirements. Choosing a ground-fault circuit interrupter addresses personnel protection against shock but does not define the functional switching capability of the device.
Takeaway: Functional switching devices must be selected based on their ability to safely manage the normal operating current of the load.
Incorrect
Correct: Functional switching is intended for the routine control of electrical circuits under normal conditions. Therefore, the device must be specifically rated to handle the load current it will encounter during its service life to prevent overheating or failure.
Incorrect: Relying on a visible break in the circuit is a requirement for safety isolation under OSHA standards rather than functional control. Simply providing an adjustable trip unit focuses on the protective functions of a circuit breaker rather than the operational switching requirements. Choosing a ground-fault circuit interrupter addresses personnel protection against shock but does not define the functional switching capability of the device.
Takeaway: Functional switching devices must be selected based on their ability to safely manage the normal operating current of the load.
-
Question 8 of 20
8. Question
A technician is inspecting the electrical system of a motorhome and finds that the 120-volt receptacles located within 6 feet of the galley sink lack ground-fault circuit-interrupter (GFCI) protection. To ensure the installation complies with the National Electrical Code (NEC) for recreational vehicles, what is the best next step?
Correct
Correct: According to the National Electrical Code (NEC) Article 551.41(C), all 125-volt, single-phase, 15- and 20-ampere receptacles installed within 6 feet of a sink in a recreational vehicle must have ground-fault circuit-interrupter (GFCI) protection. This requirement ensures that occupants are protected from electric shock in areas where moisture significantly increases the risk of current leakage.
Incorrect
Correct: According to the National Electrical Code (NEC) Article 551.41(C), all 125-volt, single-phase, 15- and 20-ampere receptacles installed within 6 feet of a sink in a recreational vehicle must have ground-fault circuit-interrupter (GFCI) protection. This requirement ensures that occupants are protected from electric shock in areas where moisture significantly increases the risk of current leakage.
-
Question 9 of 20
9. Question
A commercial electrical contractor in the United States is installing a 50 kW rooftop solar photovoltaic (PV) system. The project must include a manual disconnecting means to isolate the PV power source from all other conductors in the building. According to United States electrical safety standards, which requirement must be met for this disconnecting means?
Correct
Correct: In the United States, electrical safety regulations require that the disconnecting means for a PV system be installed in a readily accessible location. It must also be capable of being locked in the open position to ensure the safety of maintenance personnel.
Incorrect
Correct: In the United States, electrical safety regulations require that the disconnecting means for a PV system be installed in a readily accessible location. It must also be capable of being locked in the open position to ensure the safety of maintenance personnel.
-
Question 10 of 20
10. Question
A US-based brokerage firm, regulated by the SEC and FINRA, is upgrading its office infrastructure to meet federal safety standards. During a risk assessment of the employee breakroom, the facilities manager identifies several 120V receptacles located within six feet of a sink. To ensure personnel protection against electric shock in accordance with United States safety requirements, which specific protective device must be installed for these outlets?
Correct
Correct: In the United States, safety regulations for commercial environments require Ground Fault Circuit Interrupters (GFCIs) in areas near water to protect personnel from electric shock. These devices monitor the balance of current between the hot and neutral conductors and quickly disconnect the power if a leakage to ground is detected at levels as low as 4 to 6 milliamperes.
Incorrect: Relying on standard thermal-magnetic circuit breakers is inadequate because they are designed to protect equipment from high-current overloads rather than protecting humans from low-level leakage. The strategy of using surge protective devices is incorrect as these only address voltage spikes and offer no protection against ground faults or electric shock. Choosing to install arc-fault circuit interrupters is also insufficient for this specific hazard, as they are designed to prevent fires from arcing rather than providing the sensitive ground-leakage protection required near water sources.
Takeaway: United States safety standards require GFCI protection near water sources to prevent electric shock by detecting low-level current imbalances.
Incorrect
Correct: In the United States, safety regulations for commercial environments require Ground Fault Circuit Interrupters (GFCIs) in areas near water to protect personnel from electric shock. These devices monitor the balance of current between the hot and neutral conductors and quickly disconnect the power if a leakage to ground is detected at levels as low as 4 to 6 milliamperes.
Incorrect: Relying on standard thermal-magnetic circuit breakers is inadequate because they are designed to protect equipment from high-current overloads rather than protecting humans from low-level leakage. The strategy of using surge protective devices is incorrect as these only address voltage spikes and offer no protection against ground faults or electric shock. Choosing to install arc-fault circuit interrupters is also insufficient for this specific hazard, as they are designed to prevent fires from arcing rather than providing the sensitive ground-leakage protection required near water sources.
Takeaway: United States safety standards require GFCI protection near water sources to prevent electric shock by detecting low-level current imbalances.
-
Question 11 of 20
11. Question
While serving as a senior compliance officer at a broker-dealer in the United States, you are reviewing a prospectus for a company that specializes in industrial electric inverters. Internal documents suggest that the company’s primary inverter line lacks sufficient protection against electric shock, potentially violating the National Electrical Code (NEC) and leading to significant legal liabilities. Under the Securities Exchange Act of 1934, what is the primary requirement for the company regarding this information in its public filings?
Correct
Correct: Under the Securities Exchange Act of 1934, US public companies are obligated to disclose material information to the public. A design flaw in electric inverters that poses a safety risk and violates the National Electrical Code is considered material because it could lead to litigation, recalls, or loss of business, all of which are important to investors.
Incorrect
Correct: Under the Securities Exchange Act of 1934, US public companies are obligated to disclose material information to the public. A design flaw in electric inverters that poses a safety risk and violates the National Electrical Code is considered material because it could lead to litigation, recalls, or loss of business, all of which are important to investors.
-
Question 12 of 20
12. Question
In a data center operated by a United States financial institution regulated by the Federal Reserve, an electrician must perform maintenance on a power distribution unit. According to federal safety standards for the control of hazardous energy, what feature must the disconnecting means possess to ensure proper isolation?
Correct
Correct: Under United States safety regulations enforced by OSHA, any device used for the isolation of hazardous energy must be lockable. This ensures that the individual performing the work has exclusive control over the energy source, preventing accidental re-energization which is critical for safety in high-stakes environments like those regulated by the Federal Reserve.
Incorrect: Relying on a non-fused switch with a visible break provides a visual check but does not meet the legal requirement for a physical lockout mechanism. Simply locating the device within a certain distance and labeling it is a requirement for identification but does not provide the necessary physical security for isolation. Using an auxiliary contact to signal a management system is a useful monitoring feature but does not fulfill the primary safety function of preventing the circuit from being closed.
Takeaway: Isolation devices must be lockable to provide maintenance personnel with exclusive control over the energy source.
Incorrect
Correct: Under United States safety regulations enforced by OSHA, any device used for the isolation of hazardous energy must be lockable. This ensures that the individual performing the work has exclusive control over the energy source, preventing accidental re-energization which is critical for safety in high-stakes environments like those regulated by the Federal Reserve.
Incorrect: Relying on a non-fused switch with a visible break provides a visual check but does not meet the legal requirement for a physical lockout mechanism. Simply locating the device within a certain distance and labeling it is a requirement for identification but does not provide the necessary physical security for isolation. Using an auxiliary contact to signal a management system is a useful monitoring feature but does not fulfill the primary safety function of preventing the circuit from being closed.
Takeaway: Isolation devices must be lockable to provide maintenance personnel with exclusive control over the energy source.
-
Question 13 of 20
13. Question
A safety auditor for a publicly traded energy firm in the United States is reviewing the electrical infrastructure of a refinery to ensure compliance with federal safety standards. The firm must disclose significant operational risks in its SEC filings, including potential hazards in Class I, Division 1 locations where flammable gases are present. The auditor is specifically examining the requirements for conduit systems to prevent the migration of explosive vapors through the electrical network.
Correct
Correct: In the United States, safety standards require sealing fittings in Class I, Division 1 locations to minimize the passage of gases and prevent an internal explosion from traveling through the conduit system.
Incorrect
Correct: In the United States, safety standards require sealing fittings in Class I, Division 1 locations to minimize the passage of gases and prevent an internal explosion from traveling through the conduit system.
-
Question 14 of 20
14. Question
When designing an electrical system for a commercial facility housing sensitive electronic equipment, which installation practice is most effective for mitigating electromagnetic interference (EMI) while remaining compliant with the National Electrical Code (NEC)?
Correct
Correct: Utilizing grounded metallic raceways provides an effective electromagnetic shield (Faraday cage effect) that shunts interference to ground, while physical separation reduces inductive coupling between power and data lines.
Incorrect: The strategy of using an isolated grounding electrode that is not bonded to the main system creates a dangerous potential difference and violates NEC safety requirements. Simply routing different circuit types in non-metallic conduits fails to provide any electromagnetic shielding and increases the risk of signal degradation. Focusing only on increasing the physical size of the grounding conductor does not address the high-frequency nature of EMI and is not a recognized method for interference suppression.
Takeaway: Effective EMI mitigation requires a combination of physical separation and a continuous, bonded metallic shielding system.
Incorrect
Correct: Utilizing grounded metallic raceways provides an effective electromagnetic shield (Faraday cage effect) that shunts interference to ground, while physical separation reduces inductive coupling between power and data lines.
Incorrect: The strategy of using an isolated grounding electrode that is not bonded to the main system creates a dangerous potential difference and violates NEC safety requirements. Simply routing different circuit types in non-metallic conduits fails to provide any electromagnetic shielding and increases the risk of signal degradation. Focusing only on increasing the physical size of the grounding conductor does not address the high-frequency nature of EMI and is not a recognized method for interference suppression.
Takeaway: Effective EMI mitigation requires a combination of physical separation and a continuous, bonded metallic shielding system.
-
Question 15 of 20
15. Question
You are a facilities compliance officer at a financial institution in the United States that is regulated by the SEC. During a periodic safety review of the firm’s regional office, you examine the hard-wired carbon monoxide (CO) alarm system to ensure it meets the National Electrical Code (NEC) requirements for life-safety equipment. Which power supply configuration is required for these devices?
Correct
Correct: According to the National Electrical Code and NFPA standards, life-safety devices like carbon monoxide alarms must have a reliable primary power source and a secondary battery backup to maintain protection during power outages.
Incorrect: Opting for a GFCI-protected circuit is incorrect because a nuisance trip could disable the alarm without warning. Relying solely on a battery-operated system is not permitted for permanent installations in new residential construction. Choosing to connect the alarms to the load side of a switch is a violation because life-safety devices must not be controlled by a standard wall switch.
Incorrect
Correct: According to the National Electrical Code and NFPA standards, life-safety devices like carbon monoxide alarms must have a reliable primary power source and a secondary battery backup to maintain protection during power outages.
Incorrect: Opting for a GFCI-protected circuit is incorrect because a nuisance trip could disable the alarm without warning. Relying solely on a battery-operated system is not permitted for permanent installations in new residential construction. Choosing to connect the alarms to the load side of a switch is a violation because life-safety devices must not be controlled by a standard wall switch.
-
Question 16 of 20
16. Question
When designing the electrical layout for a professional hair styling station where handheld electric hair dryers are the primary equipment, which safety measure must be implemented for the receptacle outlets according to the National Electrical Code (NEC)?
Correct
Correct: The National Electrical Code (NEC) requires GFCI protection for all bathroom and similar receptacles to prevent electrocution from ground faults when using handheld appliances like hair dryers.
Incorrect: Relying solely on arc-fault protection is insufficient because it is designed to detect arcing conditions that cause fires rather than ground faults that cause lethal shocks. The strategy of using non-grounding receptacles is a violation of modern safety standards and fails to provide a safe path for fault current. Opting for a surge protective device without leakage current protection does not safeguard users from electrocution if the hair dryer falls into water.
Takeaway: Receptacles in areas where hair dryers are used must have GFCI protection to ensure safety against ground-fault currents.
Incorrect
Correct: The National Electrical Code (NEC) requires GFCI protection for all bathroom and similar receptacles to prevent electrocution from ground faults when using handheld appliances like hair dryers.
Incorrect: Relying solely on arc-fault protection is insufficient because it is designed to detect arcing conditions that cause fires rather than ground faults that cause lethal shocks. The strategy of using non-grounding receptacles is a violation of modern safety standards and fails to provide a safe path for fault current. Opting for a surge protective device without leakage current protection does not safeguard users from electrocution if the hair dryer falls into water.
Takeaway: Receptacles in areas where hair dryers are used must have GFCI protection to ensure safety against ground-fault currents.
-
Question 17 of 20
17. Question
A licensed electrician is installing a new 200-amp service panelboard in a residential garage. To comply with National Electrical Code (NEC) requirements for preventing the spread of fire, what material requirement must the enclosure satisfy?
Correct
Correct: The National Electrical Code (NEC) requires that panelboards be installed in cabinets or cutout boxes made of non-combustible materials to contain any internal arcing and prevent fire from spreading.
Incorrect: Opting for polycarbonate enclosures is incorrect because standard service-entrance panels must be made of metal or other approved non-combustible materials. The strategy of lining the interior with gypsum board is not a recognized or safe method for meeting enclosure standards. Focusing on mineral wool insulation as a mounting requirement is not mandated by the NEC for standard residential panelboard installations.
Takeaway: Residential panelboard enclosures must be non-combustible to ensure that internal electrical faults do not ignite the surrounding structure.
Incorrect
Correct: The National Electrical Code (NEC) requires that panelboards be installed in cabinets or cutout boxes made of non-combustible materials to contain any internal arcing and prevent fire from spreading.
Incorrect: Opting for polycarbonate enclosures is incorrect because standard service-entrance panels must be made of metal or other approved non-combustible materials. The strategy of lining the interior with gypsum board is not a recognized or safe method for meeting enclosure standards. Focusing on mineral wool insulation as a mounting requirement is not mandated by the NEC for standard residential panelboard installations.
Takeaway: Residential panelboard enclosures must be non-combustible to ensure that internal electrical faults do not ignite the surrounding structure.
-
Question 18 of 20
18. Question
A facility manager at a corporate office in the United States is reviewing the electrical layout for a new employee kitchenette. The plan includes the installation of multiple 125-volt, single-phase, 20-ampere receptacles within 6 feet of the edge of the sink. To comply with United States safety standards for protection against electric shock in these locations, what specific requirement must be met for these receptacles?
Correct
Correct: Under United States electrical safety standards, specifically the National Electrical Code (NEC), receptacles in kitchens or within 6 feet of sinks must have GFCI protection to mitigate the risk of electric shock in wet environments.
Incorrect: The strategy of increasing the fuse rating to 30 amperes for a 20-ampere circuit would create a fire hazard and fails to provide shock protection. Choosing to set a height requirement of 48 inches is a matter of accessibility or design but does not address the fundamental requirement for ground-fault safety. Opting for arc-fault protection as a substitute for ground-fault protection is incorrect because AFCI is designed to prevent fires from arcing, whereas GFCI is specifically required for personnel protection against leakage currents in wet areas.
Takeaway: Receptacles in US kitchenettes or near sinks require GFCI protection to ensure personnel safety against electric shock.
Incorrect
Correct: Under United States electrical safety standards, specifically the National Electrical Code (NEC), receptacles in kitchens or within 6 feet of sinks must have GFCI protection to mitigate the risk of electric shock in wet environments.
Incorrect: The strategy of increasing the fuse rating to 30 amperes for a 20-ampere circuit would create a fire hazard and fails to provide shock protection. Choosing to set a height requirement of 48 inches is a matter of accessibility or design but does not address the fundamental requirement for ground-fault safety. Opting for arc-fault protection as a substitute for ground-fault protection is incorrect because AFCI is designed to prevent fires from arcing, whereas GFCI is specifically required for personnel protection against leakage currents in wet areas.
Takeaway: Receptacles in US kitchenettes or near sinks require GFCI protection to ensure personnel safety against electric shock.
-
Question 19 of 20
19. Question
A compliance audit at a US-based investment firm identifies concerns regarding the physical infrastructure of the main server room. The facility manager is overseeing the installation of a new cable trunking system that passes through several fire-rated partitions. To ensure the installation meets safety standards and minimizes operational risk as per the Dodd-Frank Act’s framework, how must these penetrations be handled?
Correct
Correct: In the United States, regulatory frameworks for financial institutions emphasize operational resilience, which includes maintaining the integrity of fire-rated assemblies. When a wiring system like cable trunking penetrates a fire-rated wall or floor, it must be sealed with approved fire-stopping materials. This ensures the fire-resistance rating is not diminished, as required by standard safety codes and SEC-aligned risk management.
Incorrect
Correct: In the United States, regulatory frameworks for financial institutions emphasize operational resilience, which includes maintaining the integrity of fire-rated assemblies. When a wiring system like cable trunking penetrates a fire-rated wall or floor, it must be sealed with approved fire-stopping materials. This ensures the fire-resistance rating is not diminished, as required by standard safety codes and SEC-aligned risk management.
-
Question 20 of 20
20. Question
In an industrial setting where combustible dust or flyings are present in sufficient quantities to create a fire hazard, what is a mandatory requirement for the selection of electrical enclosures?
Correct
Correct: The National Fire Protection Association (NFPA) 70, also known as the National Electrical Code (NEC), requires equipment in fire-risk locations to contain sparks and limit surface temperatures to prevent ignition.
Incorrect: The strategy of using ventilated enclosures with filters is often insufficient because filters can fail, allowing hazardous dust to enter the energized equipment. Relying on mounting height with standard enclosures is inadequate as combustible dust can easily reach elevated surfaces and penetrate non-sealed housings. Choosing to apply fire-retardant sprays to equipment is not a recognized substitute for proper enclosure design and does not address the risk of internal sparks escaping.
Takeaway: Electrical equipment in fire-risk locations must prevent spark emission and maintain safe surface temperatures to avoid igniting combustible materials.
Incorrect
Correct: The National Fire Protection Association (NFPA) 70, also known as the National Electrical Code (NEC), requires equipment in fire-risk locations to contain sparks and limit surface temperatures to prevent ignition.
Incorrect: The strategy of using ventilated enclosures with filters is often insufficient because filters can fail, allowing hazardous dust to enter the energized equipment. Relying on mounting height with standard enclosures is inadequate as combustible dust can easily reach elevated surfaces and penetrate non-sealed housings. Choosing to apply fire-retardant sprays to equipment is not a recognized substitute for proper enclosure design and does not address the risk of internal sparks escaping.
Takeaway: Electrical equipment in fire-risk locations must prevent spark emission and maintain safe surface temperatures to avoid igniting combustible materials.